      Feasibility of pre-treating wastewater/water to prevent/minimize reverse osmosis (RO) membrane biofouling using ozone process

      Thumbnail
      Final Report_April Yeo.pdf (1.260Mb)
      Author
      Yeo, April Yun Xuan
      Date of Issue
      2017
      School
      School of Civil and Environmental Engineering
      Abstract
      With an ever increasing world population, the demand for clean and safe drinking water also increases. As such, various disinfection techniques have been widely applied to tackle the problem of contaminated natural water sources and one such example is the use of membrane technology. However, membranes are prone to biofouling and biofouling can potentially affect the treatment process. To prevent biofouling of membranes, water/wastewater should be pre- treated. In this study, the efficiency of using ozone advanced oxidation process was investigated for potential treatment of water spiked with contaminant. The bacterium model used was the wild type Pseudomonas aeruginosa bacterial strain PA01. Experiments using 4 different rates of ozone generation (100 mg/h, 200 mg/h, 300 mg/h and 400 mg/h) to inactivate a PA01 concentration of 8×106 CFU/ml were conducted to determine the most effective ozone generation rate. The inactivation efficiency of the different rates of ozone generation was calculated and the ozone generation rate of 400 mg/h was found to be the most efficient as 100% inactivation was reached within the fastest time of 10s. Experiments using an ozone generation rate of 400 mg/h as a control were then conducted with varying concentrations of PA01 to investigate the duration needed to achieve 100% inactivation. It was also found out that as contact time increased, inactivation efficiency also increased because there were less living cells over time. Therefore, the inactivation of Pseudomonas aeruginosa was found to be dependent on the disinfectant concentration and contact time.
      Subject
      DRNTU::Engineering::Environmental engineering::Water supply
      Type
      Final Year Project (FYP)
      Rights
      Nanyang Technological University
      Collections
      • CEE Student Reports (FYP/IA/PA/PI)

      Show full item record


      NTU Library, Nanyang Avenue, Singapore 639798 © 2011 Nanyang Technological University. All rights reserved.
      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Share |    
      Theme by 
      Atmire NV
       

       


      NTU Library, Nanyang Avenue, Singapore 639798 © 2011 Nanyang Technological University. All rights reserved.
      DSpace software copyright © 2002-2015  DuraSpace
      Contact Us | Send Feedback
      Share |    
      Theme by 
      Atmire NV
       

       

      DCSIMG